Home / Products / Closed Suction System / Sterile Closed Suction Catheter
Sterile closed suction catheter with transparent sleeve and thumb control valve

loading

Sterile closed suction catheter with transparent sleeve and thumb control valve Sterile closed suction catheter with transparent sleeve and thumb control valve
Thumb control valve of a closed suction catheter for vacuum control Thumb control valve of a closed suction catheter for vacuum control
Irrigation port on a closed suction catheter for flushing the lumen Irrigation port on a closed suction catheter for flushing the lumen
Closed suction catheters in sizes 5Fr to 16Fr arranged side by side Closed suction catheters in sizes 5Fr to 16Fr arranged side by side

Sterile Closed Suction Catheter

Availability:
Product Description

This sterile closed suction catheter is designed for suctioning secretions from the airways of intubated and ventilated patients without disconnecting them from the ventilator. The catheter is enclosed in a transparent plastic sleeve that shields the operator and the environment, and is connected in-line with the breathing circuit. A thumb control valve regulates suction, and an irrigation port allows the lumen to be flushed between suction passes.

Sterile closed suction catheter with transparent sleeve and thumb control valv
image.png

Key Features:

  • Allows suctioning without disconnecting the patient from the ventilator

  • Transparent sleeve shields the operator and the environment

  • Thumb control valve for controlled suction

  • Irrigation port for flushing the catheter lumen

  • Swivel connector helps reduce torque on the airway

  • Available in sizes 5Fr to 16Fr for neonates to adults

  • Sterile, single use, individually packed

Applications:

  • Airway suctioning in intubated and ventilated patients

  • ICU and critical care ventilation

  • Operating theatre and recovery

  • Long-term ventilation and respiratory care

Important Notes:

  • Single use only. Do not reuse or resterilize.

  • Do not use if the package is damaged or opened.

  • Select a catheter size that does not exceed 50% of the internal diameter of the endotracheal tube.

  • Do not exceed the recommended suction pressure and duration.

  • Follow the instructions for use for the maximum duration of use of the closed system.

  • Use only by trained personnel.